Unscrew the 1 screw and remove the incidence polarizer G. Attach a new incidence polarizer and align it with the mark. Tighten the 1 screw with care not to move the incidence polarizer position. Note: There is not enough space between the analysis block and LCD block. Be careful not to damage nor dirty precision components LCD panel, incidence polarizer, etc. Removal of Iris Unit 1. Unscrew the 4 screws and remove the analysis case upper. Note: The incidence polarizer is installed in the analysis case upper.
Be careful not to shift the installation position nor damage it. Unscrew the 1 screw and remove the integrator hold spring.
Unscrew the 2 screws and remove the iris unit. Set the lead wire as following picture. Be careful not to touch the surface of PBS array. Adjust each item according to the table below. To maintain and ensure safety, always use the designated components for replacement parts.
If removing any clamps, lead wires or connectors, always place them back in their proper locations. Be careful not to damage the lead wires or components when using a soldering iron or similar tool. Setting Before Adjustment Set up the projector to obtain the projection distance below. Turn the zoom ring of the projector to obtain the largest size of the picture. Lighting Area Adjustment 7. Tools to be used Service Kit Part No.
TZSH : This kit is composed of 3 extension flexible cables and 5 connector extension cables. Note: Consult your dealer or Authorized Service Center for the service kit. Preparation 1. Install the lamp unit block with lamp unit cover and tighten the 3 screws fixing the lamp unit cover. Unscrew the 2 screws fixing the A-P. Connect the service kit extension cables. Board H-P. Board connector - Connector A23 on A-P.
Covering with an insulator cloth or the like to prevent a short circuit, set the A-P. Board block on the main unit. Note: Handle with care not to apply external force to connecting parts which connect the main unit and A-P.
Adjustment Procedure 7. Outline When the lighting area is off from the adjustment and color unevenness appears, adjust the lighting area into correct position.
G Reflector Adjustment 1. Loosen the 1 screw fixing the mirror adjusting lever A just until the lever can be shifted. Adjust the mirror adjusting lever A position to minimize color unevenness on the screen by shifting the lever in arrow directions.
Tighten the 1 screw. R Reflector Adjustment 1. Loosen the 1 screw fixing the mirror adjusting lever B just until the lever can be shifted.
Adjust the mirror adjusting lever B position to minimize color unevenness on the screen by shifting the lever in arrow directions. B Reflector Adjustment 1. Loosen the 1 screw fixing the mirror adjusting lever C just until the lever can be shifted. Adjust the mirror adjusting lever C position to minimize color unevenness on the screen by shifting the lever in arrow directions.
Software for Adjustment 7. Outline This projector needs computer-aided adjustments. After the software adjustments, this projector must be turned off and on again to memorize the settings.
Connect the cable between the projector and a PC as shown below. Updating the software will change the version number. Operating Procedure 1. Run software program by the keyboard entry. Note: Use the software program as below. Adjustment Tool [ServiceAE The first menu is Language selection menu. Select the port name of PC which connects with the projector, then click [Data] or [Adjustment] button. Explanation of Buttons Data: Displays the data setting menu.
Adjustment: Displays the adjustment menu. Exit: Exits this application. Explanation of Buttons Micom Data [Transmission]: Reads the microcomputer data from the file and transmits it to the projector. Micom Data [Reception]: Receives the microcomputer data from the projector and writes it in the file. Gamma Data [Transmission]: Reads the gamma data from the file and transmits it to the projector.
Gamma Data [Reception]: Receives the gamma data from the projector and writes it in the file. Uniformity Data [Transmission]: Reads the color unevenness correction data from the file and transmits it to the projector. Uniformity Data [Reception]: Receives the color unevenness correction data from the projector and writes it in the file.
Color Management Data [Transmission]: Reads the color management data from the file and transmits it to the projector. Color Management Data [Reception]: Receives the color management data from the projector and writes it in the file. Receiving and transmitting of the data Click a target button and specify a file name. Explanation of Buttons B Signal Adj.
R Signal Adj. G Signal Adj. The 8 and 2 keys on the keyboard have the same functions. If releasing the mouse or key after pressing it continuously, the data is transmitted once. The item having two or more kinds of setting values is processed two or more items. If changing the setting value using the " " or " " button or the 8 or 2 key, its color returns to black.
Stop: Discontinues the communication. This button is usually set for its inactive mode. Undo: Returns the setting value to its original state and transmits its data. The color of the text "OK" returns to black. Close: Closes this menu. Adjustment Procedure 1.
Display Flicker Adjustment menu. Click "B Signal Adj," and the blue flicker adjustment pattern will be displayed. Minimize the flicker while observing the projected pattern. Click "R Signal Adj," and the red flicker adjustment pattern will be displayed. Click "G Signal Adj," and the green flicker adjustment pattern will be displayed.
Explanation of Buttons OK: Executes automatic sub contrast and sub brightness adjustments, then closes this dialog. Cancel: Cancels this menu. Note: Use approx. Click the OK button. Board is replaced and the product serial number disappears. Note: Set the projector into standby mode POWER indicator on the projector illuminated red , and execute the procedure in 7.
Explanation of Buttons Send: Sends and writes the serial number to the projector. Receive: Receives the serial number from the projector. Close: Closes this dialog.
Setting Procedure 1. Display Serial Number menu. Click [Send] button after inputting the serial number. Board or filter sensor CF is replaced.
Correcting Procedure Clean the air filter enough before executing the correction. If the air filter is dirty, it is not possible to correct the sensor normally. Note: When cleaning is ineffective, replace the air filter with new one. It may not get good sensor correction revision data in upland environment. Before execute this adjustment, it need to assemble a projector completely. Do not cover the air inlet port or the air outlet port. Avoid setting up in places which are subject to sudden temperature changes, such as near an air conditioner or lighting equipment.
Signals need not be input. Display the adjustment menu. When "Revision of filter sensor" window is displayed and the window will close automatically in approx. Notes: If the correction cannot start normally, execute it after disconnecting the power plug of the projector and switching ON the projector again. While correcting, the software version display appears approx. Boards or Modules related to their respective descriptions. Example A: A-P. Board assembly , read the ROM data from the old P.
Board and write it in the new one according to the section 7. At this time, if the readout from the old P. Board and install them on the new one. Then, execute the self-check according to the chapter 3. If replacing A-P. Board assembly , minimize the flicker according to the chapter 4. The projector does not become standby mode. The power indicator does not illuminate red. Solder the connector properly or replace the cable, then confirm the projector becomes standby mode.
If not, go to the next. YES Confirm the interlock switch push switch on the cable between connectors K5 and K6 is ON it was pushed , and it is conducted between terminals of the switch in the state.
Check between terminal 1 and 3 of connector P1. Check between terminal 14 and 12 of connector P3. Short circuit? NO Confirm no fusion has occurred in the thermal fuse installed in side of the lamp house. The projector does not change from standby mode to an operating mode. The power indicator does not change from red to green. Confirm every connector especially, A6 is connected and the lamp unit cover is installed properly.
Connect the connectors or install the cover properly. A short circuit has occurred in terminals 8 3. Disconnect the connector A6, check between terminal , , , , , Q, Q k Q, Q Approx. Several k. Confirm resistance values between D positive and S negative of Q and Q are hundreds k or more. Confirm every connector and the lamp unit are connected properly, and the lamp unit cover is installed. At the same time, confirm the lamp unit fixing screws are tightened. Check every fan connector.
If the connection is properly and the fan is not rotated, replace it. Then confirm the lamp lights up. Replace abnormal thermosensor, then confirm the lamp lights up. Confirm the ballast to generate a high-voltage pulse train and emits a sparking sound. Confirm that no short circuit has occurred between connector P2 pins 1 and 3. Confirm that no short circuit has occurred between connector P2 pins 4 and 3. LAMP indicator flashes.
The lamp lamplights lightsup upabnormally. YES If the lamp goes out approximately 10 minutes after it lights up, the cumulative usage time of it exceeds 2 hours. Replace the lamp.
Abnormally high temperature is detected inside the projector and TEMP indicator illuminates or flashes. Check the following: Thermal sensor connectors A11 and A7 are connected. The ambient temperature is less than The air filter does not accumulate dust. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.
Page Troubleshooting The lens cover may still be attached to the lens. The lens focus may not have been set correctly. The projector may not be at the correct distance from the screen. The picture is fuzzy. The lens may be dirty. Page Appendix The projector and the ceiling mount bracket are designed for sufficient safety. However, make sure the safety cable provided with the projector is installed and attached to the bottom of the projector when mounting on the ceiling for safety and security.
Each product has an individual variability in weight. Page Index Index Accessories Print page 1 Print document 36 pages. Rename the bookmark. Delete bookmark? Cancel Delete.